![Logo BD CONNECT - Carre - fond transpare](https://static.wixstatic.com/media/1b8155_2d66383ef9794f62a1709be277ed14a6~mv2.png/v1/fill/w_253,h_210,al_c,q_85,usm_0.66_1.00_0.01,enc_auto/Logo%20BD%20CONNECT%20-%20Carre%20-%20fond%20transpare.png)
The fast, economical and safe solution for tight gas installations and connections.
![PLT 2 bar](https://static.wixstatic.com/media/1b8155_2fa64e47778e4235ab815cd42f7aba17~mv2.png/v1/fill/w_100,h_100,al_c,q_85,usm_0.66_1.00_0.01,enc_auto/picto_pression.png)
up to 2 bar
![Couronnes PLT BD CONNECT](https://static.wixstatic.com/media/1b8155_8092732d8bf34031b7873ed39b2713fc~mv2.jpg/v1/fill/w_93,h_84,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/1b8155_8092732d8bf34031b7873ed39b2713fc~mv2.jpg)
BD CONNECT experience.
The BD CONNECT® PLT Kit enables gas installations without welding or brazing downstream of the main switchgear. It is a tight metal pipe system once assembled.
The corrugated stainless steel BD CONNECT® with a yellow anti-corrosion protection pipe in polyethylene is manually foldable.
The BD CONNECT® PLT Kit is available in rolls from 30 to 90 meters, for an operating pressure up to 500 mbar.
![](https://static.wixstatic.com/media/1b8155_1659edeb36c34cf29983a49445ab2e31~mv2.jpg/v1/fill/w_147,h_98,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/1b8155_1659edeb36c34cf29983a49445ab2e31~mv2.jpg)
BD CONNECT PLT Kit advantages.
Secure and optimize your Natural Gas and Butane Propane installations.
![PLT simple d'utilisation](https://static.wixstatic.com/media/1b8155_75ee88f2e8404d8b89631830826712cf~mv2.png/v1/fill/w_76,h_88,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/Pouce_edited_edited.png)
EASY
Easy to carry
Lightweight
Manually foldable
![PLT rapide d'installation](https://static.wixstatic.com/media/1b8155_c38a8112cd574148a55b4d6627be753c~mv2.png/v1/fill/w_92,h_87,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/Chrono_edited.png)
FAST
Save time
Without welding
Quick couplings
![PLT assurant sécurité](https://static.wixstatic.com/media/1b8155_f2c6aea2d77b4199b3231a65d28b6248~mv2.png/v1/fill/w_80,h_88,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/Sans%2520flamme_edited.png)
SAFE
No flame on site
Metal / metal sealing
Reductionof thefts on site
![PLT économique](https://static.wixstatic.com/media/1b8155_3d50515cc7844e39a491a74621828258~mv2.png/v1/fill/w_76,h_88,al_c,q_85,usm_0.66_1.00_0.01,blur_3,enc_auto/Economie_edited.png)
ECONOMICAL
Improved productivity
Reduced equipment costs
![](https://static.wixstatic.com/media/1b8155_7773528edefd47eca0f21553e8c391fe~mv2.jpg/v1/fill/w_147,h_98,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/1b8155_7773528edefd47eca0f21553e8c391fe~mv2.jpg)
Assembly steps
Kit PLT BD CONNECT .
![Etape 1 PLT BD CONNECT](https://static.wixstatic.com/media/1b8155_3a187bf969ec4fd28dc87b5d55817575~mv2.jpg/v1/fill/w_61,h_41,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/1b8155_3a187bf969ec4fd28dc87b5d55817575~mv2.jpg)
Step 1
Determine the required length then cut the pipe PLT BD CONNECT
through the sheath using the pipe cutter.
The cutting plane is located in wave troughs.
![Etape 2 PLT BD CONNECT](https://static.wixstatic.com/media/1b8155_ac2985f9a155432597a308832b3b15c0~mv2.jpg/v1/fill/w_61,h_41,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/1b8155_ac2985f9a155432597a308832b3b15c0~mv2.jpg)
2nd step
Strip the first 6 waves using a safety knife.
It is essential to respect the number of 6 waves to be stripped
Step 3
Insert the pipe
PLT BD CONNECT
into the fitting up to the stop.
Push the pipe in until the stripped stainless steel part has completely disappeared
![Etape 3 PLT BD CONNECT](https://static.wixstatic.com/media/1b8155_1659edeb36c34cf29983a49445ab2e31~mv2.jpg/v1/fill/w_61,h_41,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/1b8155_1659edeb36c34cf29983a49445ab2e31~mv2.jpg)
Step 4
Remove the safety ring (yellow) from the fitting
PLT BD CONNECT .
![Etape 4 PLT BD CONNECT](https://static.wixstatic.com/media/1b8155_7773528edefd47eca0f21553e8c391fe~mv2.jpg/v1/fill/w_61,h_41,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/1b8155_7773528edefd47eca0f21553e8c391fe~mv2.jpg)
![Etape 5 PLT BD CONNECT](https://static.wixstatic.com/media/1b8155_304f8815060a47ab84195f900f202cf8~mv2.jpg/v1/fill/w_61,h_44,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/1b8155_304f8815060a47ab84195f900f202cf8~mv2.jpg)
Step 5
Once the above operations have been completed, tighten the nut by hand, then finish with wrenches.
The nuts are tightened to the stop (zero play), the body of the fitting must remain fixed.
![Etape 6 PLT BD CONNECT](https://static.wixstatic.com/media/1b8155_b33b44d61c82478c93b42213d53a6cc4~mv2.jpg/v1/fill/w_61,h_41,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/1b8155_b33b44d61c82478c93b42213d53a6cc4~mv2.jpg)
Step 6
The protective coating removed during the implementation or assembly of the connections of the PLT BD CONNECT kit must be reconstituted by the use of adhesive strips.
![](https://static.wixstatic.com/media/1b8155_b33b44d61c82478c93b42213d53a6cc4~mv2.jpg/v1/fill/w_147,h_98,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/1b8155_b33b44d61c82478c93b42213d53a6cc4~mv2.jpg)
PLT BD CONNECT range.
Access all the references of our BD CONNECT PLT kit.